Local Engineering Context
Portsmouth Ground & Substructure Context
High coastal water tables across Portsea Island clay/alluvium necessitate Type B/C tanking, raised flood-mitigated FFLs, and piled foundations.
South East England · England · NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing)
Our roofing estimating service for Portsmouth projects translates architectural, structural, and engineering drawings into transparent NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing) schedules. Whether tendering across South East England under JCT or NEC procurement, every takeoff accounts for island-city dense brownfield housing/pbsa schemes, naval heritage dockyard stonework refurbishments, marine engineering sheds, and extensions.
Local Engineering Context
High coastal water tables across Portsea Island clay/alluvium necessitate Type B/C tanking, raised flood-mitigated FFLs, and piled foundations.
Local Engineering Context
Channel gale exposure drives enhanced roof clip/sarking specs, salt-resistant masonry mortar grades, and heavy-duty coastal glazing. Scheduled in line with Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3.
Local Engineering Context
Tight Victorian terrace plots on Portsea Island limit skip/scaffold footprints and require clean urban waste management.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing) measured in m2, m, nr | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3 | England statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | Portsmouth logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
UK weather leaves zero margin for missed flashings or under-counted valleys. Measuring pitched surfaces from roof plans and elevations, we account for eaves Overlaps, dry-fix ridges/hips, Lead/GRP valley troughs, parapet cappings, tapered PIR schemes, and rainwater goods.
Tight Victorian terrace plots on Portsea Island limit skip/scaffold footprints and require clean urban waste management. Alongside Converts flat CAD plan footprints accurately using the true roof pitch angle before deducting lanterns or chimneys. Our Excel workbooks separate measured quantities cleanly from site-specific prelim and access allowances.
Upload scaled PDFs, DWG/DXF CAD files, Revit/IFC BIM models, or NBS specifications directly via our online tender desk—every roofing estimating pack returns editable Excel schedules and marked-up PDF sheets.
Yes. BS 5534 dry-fix ridge kits, mechanical tile clips, felt eaves trays, dry verges, and over-fascia vents are all itemised.