Local Engineering Context
Brighton & Hove Ground & Substructure Context
Upper Cretaceous Chalk dipping into flint-rich coastal cliffs creates stepped retaining walls, soakaway borewells, and hand-excavated basement vaults.
South East England · England · NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing)
Our roofing estimating service for Brighton & Hove projects translates architectural, structural, and engineering drawings into transparent NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing) schedules. Whether tendering across South East England under JCT or NEC procurement, every takeoff accounts for regency stucco/mathematical-tile townhouse conversions, seafront commercial hospitality fit-outs, steep chalk-down extensions, and urban flats.
Local Engineering Context
Upper Cretaceous Chalk dipping into flint-rich coastal cliffs creates stepped retaining walls, soakaway borewells, and hand-excavated basement vaults.
Local Engineering Context
Direct English Channel salt winds mandate breathable mineral lime renders, marine-grade hardware on sash/aluminium windows, and Lead Code 5/6 valleys. Scheduled in line with Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3.
Local Engineering Context
Tight Regency one-way streets, resident bay suspension permits, and scaffold/hoist requirements across multi-storey listed facades.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing) measured in m2, m, nr | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3 | England statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | Brighton & Hove logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
UK weather leaves zero margin for missed flashings or under-counted valleys. Measuring pitched surfaces from roof plans and elevations, we account for eaves Overlaps, dry-fix ridges/hips, Lead/GRP valley troughs, parapet cappings, tapered PIR schemes, and rainwater goods.
Tight Regency one-way streets, resident bay suspension permits, and scaffold/hoist requirements across multi-storey listed facades. Alongside Converts flat CAD plan footprints accurately using the true roof pitch angle before deducting lanterns or chimneys. Our Excel workbooks separate measured quantities cleanly from site-specific prelim and access allowances.
Upload scaled PDFs, DWG/DXF CAD files, Revit/IFC BIM models, or NBS specifications directly via our online tender desk—every roofing estimating pack returns editable Excel schedules and marked-up PDF sheets.
Yes. BS 5534 dry-fix ridge kits, mechanical tile clips, felt eaves trays, dry verges, and over-fascia vents are all itemised.