Local Engineering Context
CF10 Access, Hoists & Logistics Constraints
High-water-table Bay soils paired with Central Station public-realm interfaces and SAB SuDS attenuation compliance.
Wales (Cardiff, Swansea & Regional) · Wales · NRM2 Sections 33–36 (Roads, Drainage & Utilities)
Tendering work within CF10 (Cardiff Central & Cardiff Bay) demands tight cost clarity before mobilising to site. Our sitework estimating schedules capture exact net NRM2 Sections 33–36 (Roads, Drainage & Utilities) quantities while separating prelims and material handling considerations driven by civic offices, mixed-use waterfront apartments, university tech suites, and hospitality fit-outs.
Local Engineering Context
High-water-table Bay soils paired with Central Station public-realm interfaces and SAB SuDS attenuation compliance.
Local Engineering Context
Civic offices, mixed-use waterfront apartments, university tech suites, and hospitality fit-outs.
Local Engineering Context
Welsh Approved Documents, SuDS SAB drainage detailing, and commercial MEP / steel structure scheduling.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Sections 33–36 (Roads, Drainage & Utilities) measured in m, m2, m3, nr | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Wales) Approved Documents & Welsh SuDS SAB Mandatory Drainage Approval | Wales statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | CF10 Postcode District logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
Civil external works frequently hold the largest hidden contingencies on UK residential and commercial developments. Cross-referencing engineering drainage longs and road sections, we measure pipe invert depths, precast concrete manholes, interceptors, SuDS geocellular crates, binder/surface asphalt courses, and street lighting.
High-water-table Bay soils paired with Central Station public-realm interfaces and SAB SuDS attenuation compliance. Separating physical net BoQ items from phased call-offs and urban logistics lets contractors price risk transparently without diluting trade rates.
Yes. Adoptable Type A/B manholes, clay/twinwall pipes, and public connections are split cleanly from private plot gullies and ACO channels.
Yes. Tactile blister flags, transition kerbs, thermoplastic white lining, bollards, and lighting duct/base pits are measured completely.