Local Engineering Context
Leeds Ground & Substructure Context
Coal Measures geology, River Aire flood-alleviation levels, and stepped hillsides drive retaining concrete walls and bulk muck-away earthworks.
Yorkshire and the Humber · England · NRM2 Section 14 (Masonry)
Our masonry estimating service for Leeds projects translates architectural, structural, and engineering drawings into transparent NRM2 Section 14 (Masonry) schedules. Whether tendering across Yorkshire and the Humber under JCT or NEC procurement, every takeoff accounts for commercial headquarters, south bank regeneration quarters, regional housebuilding in yorkshire stone & brick, and industrial distribution sheds.
Local Engineering Context
Coal Measures geology, River Aire flood-alleviation levels, and stepped hillsides drive retaining concrete walls and bulk muck-away earthworks.
Local Engineering Context
High Pennine wind exposure places emphasis on mechanical BS 5534 pitched roof fixings, natural blue slate/stone details, and thermally broken glazing. Scheduled in line with Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3.
Local Engineering Context
Split between constrained city-loop corporate fit-outs and large suburban estates with strong access along the M1 and M62 corridors.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Section 14 (Masonry) measured in m2, nr, m, tonnes | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3 | England statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | Leeds logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
UK brickwork packages demand exact opening deductions, reveal return closures, stepped cavity trays at roof abutments, windposts, and fire-rated movement joints. We convert wall elevations and sections into clean masonry subcontractor and merchant schedules.
Split between constrained city-loop corporate fit-outs and large suburban estates with strong access along the M1 and M62 corridors. Alongside Uses standard UK metric modular brick counts (60 bricks/m2 single leaf with mortar joints) and 10 blocks/m2 per 100mm/140mm/215mm leaf. Our Excel workbooks separate measured quantities cleanly from site-specific prelim and access allowances.
Upload scaled PDFs, DWG/DXF CAD files, Revit/IFC BIM models, or NBS specifications directly via our online tender desk—every masonry estimating pack returns editable Excel schedules and marked-up PDF sheets.
Yes. Multi-storey stainless-steel masonry support angles, windposts, head restraints, and wall starters shown on structural details are counted cleanly.