Local Engineering Context
London Ground & Substructure Context
Shrinkable London Clay over Thames Terrace Gravels routinely drives deep piling, contiguous secant walls, and Grade 3 BS 8102 basement waterproofing.
Greater London · England · NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling)
Our doors & windows estimating service for London projects translates architectural, structural, and engineering drawings into transparent NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling) schedules. Whether tendering across Greater London under JCT or NEC procurement, every takeoff accounts for high-density basements, prime central heritage refurbishments, build-to-rent towers, and complex cat a/b city & west end commercial fit-outs.
Local Engineering Context
Shrinkable London Clay over Thames Terrace Gravels routinely drives deep piling, contiguous secant walls, and Grade 3 BS 8102 basement waterproofing.
Local Engineering Context
Street-facing acoustic dB glazing, heritage sliding sashes in conservation areas, and strict Building Safety Act HRB passive firestopping across residential towers. Scheduled in line with Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3.
Local Engineering Context
Pit-lane loading bays, FORS/CLOCS transport compliance, Congested/ULEZ zones, hoist hire, and tight material laydown windows requiring phased call-offs.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling) measured in nr, m2, m, sets | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3 | England statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | London logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
Nothing derails a fenestration or fit-out bid faster than mismatched architectural window schedules and plan openings. We reconcile every opening—PPC aluminium frames, composite heritage casements, structural glass roofs, automatic entrance doors, and FD30S/FD60S fire doorsets.
Pit-lane loading bays, FORS/CLOCS transport compliance, Congested/ULEZ zones, hoist hire, and tight material laydown windows requiring phased call-offs. Alongside Cross-checks structural opening width/height against elevation drawings and highlights conflicts in an RFI tab. Our Excel workbooks separate measured quantities cleanly from site-specific prelim and access allowances.
Upload scaled PDFs, DWG/DXF CAD files, Revit/IFC BIM models, or NBS specifications directly via our online tender desk—every doors & windows estimating pack returns editable Excel schedules and marked-up PDF sheets.
Yes. Discrepancies in opening counts, handing (LH/RH), fire escapes, or U-values/acoustic specs are flagged immediately on our discrepancy log.