South East England · England · NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling)

Doors & Windows Estimating for Surrey Construction Tenders

Serving builders, specialist subcontractors, and developers working throughout Surrey, our doors & windows estimating service delivers transparent NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling) bills of quantities calibrated around high-value bespoke detached houses, basement cinema/pool excavations, oak-framed additions, and guildford/woking commercial suites.

Local Engineering Context

Surrey Geology & Substructure Drivers

Bagshot Sands, Weald Clay, and North Downs Chalk pockets requiring clear drainage/soakaway feasibility splits.

Local Engineering Context

County Planning & Material Specifications

Surrey Hills AONB natural limestone, handmade clay tiles, and high-spec architectural glazing suites.

Local Engineering Context

Transport & Site Prelims Considerations

Strict Tree Preservation Orders (TPOs) & constrained residential estate roadways demand careful temporary ground-protection takeoffs.

Measurement & Deliverable Parameters

How are Surrey doors & windows packages measured and delivered?

Doors & Windows Estimating in Surrey County — NRM2 Parameters & Deliverables
Estimating ParameterTechnical SpecificationStandard / Audit Basis
Measurement Section & UnitsNRM2 Section 24 & 25 (Doors, Windows & Curtain Walling) measured in nr, m2, m, setsScaled GA plans at 1:50 / 1:100 or structural details in mm
Local Statutory FrameworkBuilding Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3England statutory & local tender compliance notes
Wastage & Prelim SeparationNet quantities isolated with 5%–10% typical trade waste allowancesSurrey County logistics and phased delivery allowances
Deliverables & Drawing Uploads100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload)24–48 hrs turnaround target for focused single-trade packages

Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.

What is measured in every Surrey pack?

Nothing derails a fenestration or fit-out bid faster than mismatched architectural window schedules and plan openings. We reconcile every opening—PPC aluminium frames, composite heritage casements, structural glass roofs, automatic entrance doors, and FD30S/FD60S fire doorsets.

  • Cross-checks structural opening width/height against elevation drawings and highlights conflicts in an RFI tab.
  • Distinguishes Part Q laminated security glass, acoustic attenuation dB units, and obscure bathroom glazing.

Which drawings and UK project types are supported?

  • Door & window schedules
  • Architectural floor plans & elevations
  • Fire strategy & Secured by Design (Part Q) specs

Suitable UK Project Types

Aluminium apartment window packsHigh-street shopfronts & curtain wallsHeritage sash conservation replacementsCommercial internal glazed partitions & FD doors

Doors & Windows Estimating FAQs for Surrey

What does a Surrey doors & windows estimate include?

Every workbook provides net measured quantities in nr, m2, m, sets, colour-coded PDF drawing mark-ups, separated material vs labour lines, and clarifications covering Surrey site requirements.

Do you check if window schedules match what is actually drawn on plans and elevations?

Yes. Discrepancies in opening counts, handing (LH/RH), fire escapes, or U-values/acoustic specs are flagged immediately on our discrepancy log.

Are pressed aluminium cills, cavity closers, and expanding foam/Compacfoam packs included?

Yes. Cill projections, head closers, perimeter EPDM weather-sealing, and acoustic mastic are itemised cleanly.