Local Engineering Context
Surrey Geology & Substructure Drivers
Bagshot Sands, Weald Clay, and North Downs Chalk pockets requiring clear drainage/soakaway feasibility splits.
South East England · England · NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling)
Serving builders, specialist subcontractors, and developers working throughout Surrey, our doors & windows estimating service delivers transparent NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling) bills of quantities calibrated around high-value bespoke detached houses, basement cinema/pool excavations, oak-framed additions, and guildford/woking commercial suites.
Local Engineering Context
Bagshot Sands, Weald Clay, and North Downs Chalk pockets requiring clear drainage/soakaway feasibility splits.
Local Engineering Context
Surrey Hills AONB natural limestone, handmade clay tiles, and high-spec architectural glazing suites.
Local Engineering Context
Strict Tree Preservation Orders (TPOs) & constrained residential estate roadways demand careful temporary ground-protection takeoffs.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Section 24 & 25 (Doors, Windows & Curtain Walling) measured in nr, m2, m, sets | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3 | England statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | Surrey County logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
Nothing derails a fenestration or fit-out bid faster than mismatched architectural window schedules and plan openings. We reconcile every opening—PPC aluminium frames, composite heritage casements, structural glass roofs, automatic entrance doors, and FD30S/FD60S fire doorsets.
Every workbook provides net measured quantities in nr, m2, m, sets, colour-coded PDF drawing mark-ups, separated material vs labour lines, and clarifications covering Surrey site requirements.
Yes. Discrepancies in opening counts, handing (LH/RH), fire escapes, or U-values/acoustic specs are flagged immediately on our discrepancy log.
Yes. Cill projections, head closers, perimeter EPDM weather-sealing, and acoustic mastic are itemised cleanly.