Local Engineering Context
Hampshire Geology & Substructure Drivers
South Downs Chalk contrasted with New Forest gravels and coastal estuarine clays along Solent ports.
South East England · England · NRM2 Section 22 & 25 (First & Second Fix Joinery)
Serving builders, specialist subcontractors, and developers working throughout Hampshire, our carpentry estimating service delivers transparent NRM2 Section 22 & 25 (First & Second Fix Joinery) bills of quantities calibrated around marine/commercial estates, solent logistics, family housing estates, and rural heritage brick-and-flint homes.
Local Engineering Context
South Downs Chalk contrasted with New Forest gravels and coastal estuarine clays along Solent ports.
Local Engineering Context
Nitrate-neutrality drainage attenuation & New Forest conservation craft joinery specs.
Local Engineering Context
Coastal salt-air marine-grade stainless steel & coated cladding requirements in portside zones.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Section 22 & 25 (First & Second Fix Joinery) measured in m, m2, nr, sets | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Approved Documents Parts A–S) & Building Safety Act (BSA) Gateways 1–3 | England statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | Hampshire County logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
Keeping carpentry tenders profitable means separating gang-rate first-fix structural carcasses from delicate second-fix FD30/FD60 fire doorset hanging and high-end joinery. We break down every timber dimension, fixing clip, and ironmongery set clearly.
Every workbook provides net measured quantities in m, m2, nr, sets, colour-coded PDF drawing mark-ups, separated material vs labour lines, and clarifications covering Hampshire site requirements.
Yes. Workbooks split fixings/ironmongery supply counts cleanly alongside per-plot or per-door labour items.
Yes. P5 structural chipboard/OSB floor decking, D4 adhesive, noggins, and acoustic resilience bars are quantified cleanly.