Local Engineering Context
Glamorgan (Cardiff & Swansea Corridor) Geology & Substructure Drivers
Coastal mudflats, Coal Measures Valley profiles, and limestone cliffs demanding Welsh SAB SuDS storage.
Wales (Cardiff, Swansea & Regional) · Wales · NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing)
Serving builders, specialist subcontractors, and developers working throughout Glamorgan (Cardiff & Swansea Corridor), our roofing estimating service delivers transparent NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing) bills of quantities calibrated around bay-area mixed commercial blocks, student/residential towers, industrial light engineering units, and terraced refurbishments.
Local Engineering Context
Coastal mudflats, Coal Measures Valley profiles, and limestone cliffs demanding Welsh SAB SuDS storage.
Local Engineering Context
Pennant stone walls, Welsh slate pitched roofs, and high-exposure wet-dash rendered assemblies.
Local Engineering Context
Welsh SAB surface-water regulation makes permeable sub-base & attenuation crate lines essential on almost all sites.
Measurement & Deliverable Parameters
| Estimating Parameter | Technical Specification | Standard / Audit Basis |
|---|---|---|
| Measurement Section & Units | NRM2 Sections 17–18 (Sheet & Tile/Slate Roofing) measured in m2, m, nr | Scaled GA plans at 1:50 / 1:100 or structural details in mm |
| Local Statutory Framework | Building Regulations (Wales) Approved Documents & Welsh SuDS SAB Mandatory Drainage Approval | Wales statutory & local tender compliance notes |
| Wastage & Prelim Separation | Net quantities isolated with 5%–10% typical trade waste allowances | Glamorgan (Cardiff & Swansea Corridor) County logistics and phased delivery allowances |
| Deliverables & Drawing Uploads | 100% open-formula Excel BoQ + colour-coded PDF overlays (up to 25 MB upload) | 24–48 hrs turnaround target for focused single-trade packages |
Calibration note: 1:50 and 1:100 architectural and structural drawings are scaled to 25 mm masonry tolerances and 100 mm thermal zones, isolating 5 percent to 10 percent wastage from net quantities.
UK weather leaves zero margin for missed flashings or under-counted valleys. Measuring pitched surfaces from roof plans and elevations, we account for eaves Overlaps, dry-fix ridges/hips, Lead/GRP valley troughs, parapet cappings, tapered PIR schemes, and rainwater goods.
Every workbook provides net measured quantities in m2, m, nr, colour-coded PDF drawing mark-ups, separated material vs labour lines, and clarifications covering Glamorgan (Cardiff & Swansea Corridor) site requirements.
Yes. BS 5534 dry-fix ridge kits, mechanical tile clips, felt eaves trays, dry verges, and over-fascia vents are all itemised.
Yes. Fall zones, crickets, sump outlets, vapour control layers, and single-ply / Felt capping sheets are broken out cleanly.